OXYGEN FREE COPPER ROD
![]() |
![]() |
Technical data
Product: Copper wire rod of diameter (8±0.40) mm, produced by continuous casting named “UPCAST”
Standard: BDS EN 1977:2003
Material used in production: Copper cathodes grade designation Cu-CATH-1 acc. to BDS EN 1978:2002.
Typical chemical composition:
Cu – 99.99% |
|||||||||||
ppm |
|||||||||||
Ag |
Al |
As |
Bi |
Cd |
Co |
Cr |
Fe |
Mg |
Mn |
NI |
S |
6.56 |
<0.080 |
1.23 |
0.348 |
<0.35 |
0.303 |
0.208 |
8.627 |
<0.10 |
<0.11 |
<0.20 |
5.257 |
P |
Pb |
Sb |
Se |
Si |
Sn |
Te |
Zn |
Zr |
H |
O |
|
0.75 |
0.728 |
1.123 |
<0.65 |
1.16 |
<0.65 |
<2,7 | <1.1 | <0.090 | 0.30 | <2.0 |
Physical properties:
Tensile strength : min 170 MPa
Elongation : min 40 %
Resistance in 20°C: max. 0.01707 Ω.mm2 /m
Packing: The rod is supplied on coils of approximately 3000 kg weight in one piece without joins. The coils are transported on wooden pallets secured to the pallets with plastic straps. Every coil is covered with plastic foil for protection against adverse conditions. The surface of rod is coated with anti-corrosion synthetic wax layer which secures against oxidation during transport and storage.
COPPER CONDUCTORS OF CABLES, WIRES AND FLEXIBLE CORDS
Application
The conductors are intended to use different types of cables, wires and cords
Technical data
- manufactured acc. to IEC 60228
- the conductors may be wound on metal and wooden drums of different sizes
- the conductors of 1,5 mm2 to 10 mm2 - class 1 may be wound in metal containers
Conductor design
- solid conductors class 1 acc. to IEC 60228
-
stranded conductors class 2, 5, 6 acc. to IEC 60228
Conductor cross section | class 1 acc. to IEC 60228 | class 2 acc. to IEC 60228 | ||
Weight | Conductor diameter | Weight | ||
mm2 | kg/km | mm | kg/km | |
0,50 | 4,8 | 0,9 | 4,8 | |
0,75 | 7,2 | 1,1 | 7,2 | |
1,00 | 9,6 | 1,3 | 9,6 | |
1,50 | 14,4 | 1,6 | 14,4 | |
2,50 | 24,0 | 2,0 | 24,0 | |
4,00 | 38,4 | 2,5 | 38,4 | |
6,00 | 57,6 | 3,1 | 57,6 | |
10,00 | 96,0 | 4,0 | 96,0 | |
16,00 | 153,6 | 5,0 | 153,6 | |
25,00 | 6,3 | 240,0 | ||
35,00 | 7,4 | 336,0 | ||
50,00 | 8,7 | 480,0 | ||
70,00 | 10,5 | 672,0 | ||
95,00 | 12,3 | 912,0 | ||
Conductor cross section | class 5 acc. to IEC 60228 | class 6 acc. to IEC 60228 | ||
Conductor diameter | Weight | Conductor diameter | Weight | |
mm2 | mm | kg/km | mm | kg/km |
0,50 | 0,9 | 4,8 | 0,9 | 4,8 |
0,75 | 1,2 | 7,2 | 1,1 | 7,2 |
1,00 | 1,3 | 9,6 | 1,3 | 9,6 |
1,50 | 1,6 | 14,4 | 1,6 | 14,4 |
2,50 | 2,0 | 24,0 | 2,2 | 24,0 |
4,00 | 2,5 | 38,4 | 2,9 | 38,4 |
6,00 | 3,2 | 57,6 | 3,7 | 57,6 |
10,00 | 5,0 | 96,0 | 4,6 | 96,0 |
16,00 | 5,8 | 153,6 | 6,0 | 153,6 |
25,00 | 7,3 | 240,0 | ||
35,00 | 9,1 | 336,0 | ||
50,00 | 11,0 | 480,0 | ||
70,00 | 13,4 | 672,0 | ||
95,00 | 14,2 | 912,0 | ||
120,00 | 16,2 | 1152,0 |